Yokogawa Button Operated MV2000 Instrukcja Użytkownika Strona 161

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 177
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 160
7-8
M-4662
InputRegister Data DataType
36001 List of alarms of measurement channels 001 to 004 Bit string
| |
36012 List of alarms of measurement channels 045 to 048
Register structure
4ch 3ch 2ch 1ch
Level 3
Level 4
Level 2
Level 1
Indicates the alarm statuses of four channels in a register. Set to 1 when
alarm is activated. The figure above is an example of register 36001
(measurement channels 001 to 004).
36021 List of alarms of computation channels 101 to 104 Bit string
| |
36035 List of alarms of computation channels 157 to 160
Register structure: Same as the list of alarms of measurement channels.
36041 List of alarms of external input channels 201 to 204 Bit string
| |
36100 List of alarms of external input channels 437 to 440
Register structure: Same as the list of alarms of measurement channels.
Input registers 36001 to 36100 can be accessed consecutively. All unassigned register bits
are read as zeroes.
InputRegister Data DataType
39001 Year 16-bit signed integer
39002 Month
39003 Day
39004 Hour
39005 Minute
39006 Second
39007 Millisecond
39008 (Reserved)