User’s
Manual
Yo kogawa Electric Corporation
MX100/MW100
Data Acquisition Unit
Installation and Connection Guide
Foreword
Thank you for purchasing the MX100/MW100 Data Acquisition Unit. This guide describes concisely the installation and wiring procedures of
the MX100/MW100 Data Acquisition Unit. For more details on this topic as well as safety precautions (be sure to read), and the descriptions
of the functions and operations of the MX100/MW100 Data Acquisition Unit, see the MX100/MW100 Data Acquisition Unit User’s Manual
(electronic manual in PDF format) which is contained in the CD-ROM provided.
1. Installation Procedure
of Modules
3. Terminal Arrangement Markings
4. Attaching and Removing the Terminal Block
Screw Terminal Block
Plate with screw terminals
5. Wiring Procedure
6. Connecting the Power Supply
Inserting and Ejecting the CF Card
7. Connecting to the Ethernet Interface
Contents Displayed on the 7-Segment LED
Dipswitches
*1
MX100
Types of Input/Output Modules
• 4-CH, High-Speed Universal Input Module (MX110-UNV-H04) • 10-CH, Medium-Speed Universal Input Module (MX110-UNV-M10)
30-CH, Medium-Speed DCV/TC/DI Input Module (MX110-VTD-L30)
6-CH, Medium-Speed Four-Wire RTD Resistance Input Module (MX110-V4R-M06)
• 4-CH, Medium-Speed Strain Input Module (MX112-B12-M04) • 4-CH, Medium-Speed Strain Input Module (MX112-B35-M04)
• 4-CH, Medium-Speed Strain NDIS Input Module (MX112-NDI-M04) • 10-CH, Pulse Input Module
*2
(MX114-PLS-M10)
• 10-CH, High-Speed Digital Input Module (MX115-D05-H10) • 10-CH, High-Speed Digital Input Module (MX114-D24-H10)
• 8-CH, Medium-Speed Analog Output Module (MX120-VAO-M08) • 8-CH, Meduim-Speed PWM Output Module (MX120-PWM-M08)
• 10-CH, Medium-Speed Digital Output Module (MX125-MKC-M10)
Main module
*2 Modules compatible with the MW100.
*1 Normally all dip switches are turned ON.
Used to initialize settings and for other purposes.
The figure on the left is the MX100 Main Module.
This is different from the overview of the MW100
Main Module. On the MW100, it is dip switch 1.
2. Installation Procedure
of the MX100/MW100
Overview of the Operation
1. Installation Procedure of Modules
Attaching the Module
1. Prepare the base block.
When attaching the MW100, replace the current base block BRACKET with the BRACKET that came with the MW100.
Attach the bracket that came with the MW100
Remove the base block bracket
Bracket
When attaching the MX100, if using a conventional version of the main module, remove the base block BRACKET. If the main module has
been reworked, use the existing base block as-is. See “MX100/MW100: Handling of the Base Block (Model MX150-)” in IM MX100-75.
2. Check that the power supply is not connected to the main module.
7th Edition: February 2008 (YK)
All Right Reserved, Copyright © 2005 Yokogawa Electric Corporation
IM MX100-72E
7th Edition
*MX10072E07 *
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Foreword

User’sManualYo kogawa Electric CorporationMX100/MW100Data Acquisition UnitInstallation and Connection GuideForewordThank you for purchasing the MX100/

Strona 2 - MX100 Main module

10IM MX100-72E6. Connecting the Power SupplyDATA ACQUISITION UNITPower CordPower CordProtective grounding cordProtective grounding cordPower supplyter

Strona 3 - • Attachment to a DIN Rail

11IM MX100-72E7. Connecting to the Ethernet InterfaceConnect the Ethernet cable to the Ethernet port of the mainmodule. Use a UTP cable (category 5 o

Strona 4 - Screw Terminal Block

12IM MX100-72EContents Displayed on the 7-Segment LED7-segment LEDDATAACQUIS ITIONUNITETHERNETPOWER10BASE - T100BASE - TXSWON12345678The main module h

Strona 5 - 5. Wiring Procedure

2IM MX100-72E3. Align the connector on the rear panel of the module to the connector at the desired position of the base plate and insert the connecto

Strona 6 - -B12, -B35

3IM MX100-72E2. Installation Procedure of the MX100/MW100The MX100/MW100 Data Acquisition Unit can be used on a desktop, on a floor, in a rack mount,

Strona 7 - 5. Wiring Procedure

4IM MX100-72E4. Attaching and Removing the Terminal BlockThe terminals of the input/output modules in the figure below can be removed.The terminal blo

Strona 8 - • 5-V logic input

5IM MX100-72EAttaching the Terminal Cover1. Loosen the terminal cover attachment screw, then flip up the terminal cover in the direction of the arrow

Strona 9 - 30 VDC/2 A (resistance load)

6IM MX100-72E• Wiring the 4-Wire RTD Resistance Input ModulesABICABICVotageNothing connected to the I or C terminalResistance, RTD+Resistance per lead

Strona 10 - MW100 main module

7IM MX100-72E• Opposing Two-Gauge MethodRg1Rg2Setting switchONOFFNo.1No.2No.3No.4No.5A(+V)B( L)C(-V)D( H)-B12, -B35-NDINo.1ONNo.2OFFNo.3ONNo.4OFFNo.5O

Strona 11 - • Ejecting the CF Card

8IM MX100-72E• Wiring the Pulse Input Module and Digital Input Modules (-D05, -D24)Note• With the pulse input module and digital input module, the (–)

Strona 12 - Turns off for 1 s

9IM MX100-72E• Wiring the Analog Output ModulesExternal power supply VoltageV+Load+24 Vpower supply(when using current output)Direction ofcurrentVextC