Use cables with cross section 0.08 to 0.5 mm²
Connect the cables from the external instruments to the terminals inside of the converter terminal box
(RCCT3 / RCCF31 or on terminal board (RCCR31).
Conrm two ferrite core sets are attached to the owmeter.
Insert the cable into ferrite core before connecting to the terminals. Fix the ferrite core (see gure on
page 4-16)
Connect the cables to the terminals according to the gure below.
I/O-Terminal Overview :
Receiving instrument
ROTAMASS
Iout -
Iout +
+
-
-
Load resistance max. 600 Ω
F411.EPS
1. Analog signal output (Iout 1 and Iout 2)
ROTAMASS has 2 analog outputs, 4 to 20 mA DC.
Load resistance 20- 600 (/KF2 has only one analog output, which is intrinsic safe. See chapter 4.8.8).