Yokogawa PH18 Differential pH Sensor Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Yokogawa PH18 Differential pH Sensor. Yokogawa PH18 Differential pH Sensor User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Instruction
Manual
Model PH18
Differential pH sensor
IM 12B6J4-E-A
2nd Edition
Yokogawa Corporation of America
2 Dart Road, Newnan, Georgia U.S.A. 30265
Tel: 1-800-258-2552 Fax: 1-770-254-0928
IM 12B6J4-E-A
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - Instruction

InstructionManualModel PH18Differential pH sensorIM 12B6J4-E-A2nd EditionYokogawa Corporation of America2 Dart Road, Newnan, Georgia U.S.A. 30265Tel:

Strona 2 - TABLE OF CONTENTS

10IM 12B6J4-E-AAll Rights Reserved. Copyright © 2003, Yokogawa Corporation of America. Subject to change without notice.July 9, 2012GS 12B6J4-01E-A 4

Strona 3

11IM 12B6J4-E-A3. THE TYPE 18 PH PROBE3-1. Typical applications• Fermentation• Continuous reactions• Production of diary products• Product monitoring3

Strona 4

12IM 12B6J4-E-AExample A. Straight weld-in adapter through a vessel wall.Example B. 1” Screw-in adapter with existing pipe

Strona 5

13IM 12B6J4-E-A4. EXA PH202/FLXA21 or PH402/ PH450 INSTRUMENT4-1. Set-up PH202/PH402The EXA PH202/FLXA21 and PH402/PH450 are all designed with dua

Strona 6 - 1. INTRODUCTION

14IM 12B6J4-E-A5-4. ASYMMETRY PotentialThe default setting for Asymmetry potential is 0 mV at Isopotential pH value. This value is always wrong for th

Strona 7

15IM 12B6J4-E-AThe probe can be cleaned/sterilized inside the reactor. For CIP cleaning it must be ensured that the admissible alkali and acid concent

Strona 8 - 2. GENERAL SPECIFICATIONS

16IM 12B6J4-E-A8. POSITION OF THE O-RINGSENGLISHIM 12B6J4-ED-H148. POSITION OF THE O-RINGS9. ACCESSORIESl PH18 differential pH sensorAC D AB

Strona 9

17IM 12B6J4-E-ASC24V or PH18 Application Data SheetCustomer: Please complete a seperate form for each process Tag No: stream to be analyzed and return

Strona 10 - IM 12B6J4-E-A

IM 12B6J4-E-A 02-1207 (A) ISubject to change without notice Printed in The USACopyright ® Yokogawa has an extensive sales and distribution network.

Strona 11 - 3. THE TYPE 18 PH PROBE

2IM 12B6J4-E-A PREFACE ...

Strona 13 - PH450 INSTRUMENT

4IM 12B6J4-E-ACaution - Inappropriate handling can cause damage.Striking or scratching the sensor against hard surfaces such as steel, stone, glass

Strona 14 - 5. CALIBRATION

5IM 12B6J4-E-APREFACEThe PH18 should only be used with equipment that meets the relevant IEC, American or Canadian standards. Yokogawa accepts no resp

Strona 15

6IM 12B6J4-E-A1. INTRODUCTIONThe PH18 is not a conventional electrode. It relies on two dissimilar ion sensitive enamel membranes to generate the sign

Strona 16 - 8. POSITION OF THE O-RINGS

7IM 12B6J4-E-AIM 12B6J4-E-A4Fig. 1Measuring Enamel mV vs.pH in solution containing0.1N Na+pH of sampleFig. 2Fig. 3Fig. 4Reference Enamel mV vspH in so

Strona 17

8IM 12B6J4-E-A2-1. Model PH18 differential pH sensorTemperature sensor : Pt1000 W RTDWetted parts- pH sensor : pH sensitive enamel- Referen

Strona 18 - IM 12B6J4-E-A 02-1207 (A) I

9IM 12B6J4-E-A2-2. Model WU18 cable for model PH18differential pH sensorMax. temperature :110 ºC (230 ºF)Material :Thermoplastic Rubber (T.P

Komentarze do niniejszej Instrukcji

Brak uwag