Strona 2 - Contents

9 2.10. Communication Commands 2.10.1. Setting the LOG Range Setting mode setting SR p1,p2,p3,p4,p5,p6,p7,p8,p9 <terminator> ¾ p1: Chan

Strona 3 - 1. Foreword

10 3. Accuracy and Display Resolution 3.1. Measurement and Display Accuracy (Digital Display) Computing method of the display value accuracy ¾

Strona 4 - 2. LOG Input Specifications

11 Computing example of the display value accuracy ¾ Integration time 50 Hz ¾ 2 V range Voltage span 0.0000 to 1.0000 V ¾ LOG span -2 to 3 1

Strona 5

12 4. Simulation Function 4.1. Display Freeze Function 4.1.1. Specifications A function used to stop the updating of the time, trend, digital v

Strona 6

13 Event action functions that do not operate while the display is frozen ¾ See Table 4-1. ¾ If a level action such as Memory start/stop is execut

Strona 7

14 4.1.3. Setting the Display Freeze Function 1. Press MENU (switch to the setting mode). 2. Select Timer, Event action > Event action. 3. Set th

Strona 8

15 4.2. Memory and Trend Clear Function 4.2.1. Specifications A function used to clear the internal memory and the trend. ¾ Clears the data area

Strona 9

16 4.2.3. Setting the Memory and Trend Clear Function 1. Press MENU (switch to the setting mode). 2. Select Timer, Event action > Event action. 3

Strona 10

17 4.4. Enabling/Disabling the Time Display 4.4.1. Specifications A function used to disable the time display on the operation display. Display

Strona 11 - (SU-SL)*(X-VL)/(VU-VL)+SL

18 4.4.2. Enabling/Disabling the Time Display 1. Press MENU (switch to the setting mode). 2. Hold down FUNC for 3 s to switch to the basic setting

Strona 12

1 Contents 1. Foreword ...2 2. L

Strona 13 - 4. Simulation Function

19 4.5. Special Current Value Mark Function 4.5.1. Specifications A function used to display the channel using two digits for the current value

Strona 14

20 4.5.2. Setting the Channel Display of the Current Value Mark 1. Press MENU (switch to the setting mode). 2. Hold down FUNC for 3 s to switch to t

Strona 15

2 1. Foreword Thank you for purchasing the DX1000(N)/DX2000 DXAdvanced. This user’s manual describes the functions listed below. For a description o

Strona 16

3 2. LOG Input Specifications 2.1. Converting the LOG Input (Relationship between the Input Voltage and Digital Display) Trend display (logarithm

Strona 17

4 2.2. LOG Input Mode This mode allows you to measure the DC voltage input (DCV: 20 mV, 60 mV, 200 mV, 2 V, 6 V, 20 V, and 50 V), convert to logar

Strona 18

5 Table 2-1 Log Input Mode Settings Setup Item Selectable Items (Selectable Range) Description Range Same as the DCV range Sets the range. Span Low

Strona 19

6 2.3. Alarm Alarm types in LOG input mode ¾ H, L, T, and t only. Set the alarm value using a voltage. Computing method of alarm values ¾ Co

Strona 20

7 2.4. Computation Function (Option) When a channel set to LOG is used in a computation, error data is used as its measured value. 2.5. Report